Search
Now showing items 21-30 of 36
Classification of Common Partial Discharge Types in Oil-Paper Insulation Using Acoustic Signals
(2014-02)
Power transformers' age is highly related to the strength status of its insulation system. Oil-paper insulation system is the main type of insulation for most of the power and distribution transformers in the network. ...
Shear Strength of Fiber Reinforced Recycled Aggregate Concrete
(2018-11)
In this research, the shear strength of fiber reinforced recycled concrete was investigated. A High-strength Self Consolidated Concrete (SCC) matrix with 100% coarse recycled aggregate and different types/configurations ...
Strengthening of High Strength Reinforced Concrete Slabs with CFRP Laminates
(2016-05)
During the last few decades, engineers and researchers used high-strength concrete to cast reinforced concrete (RC) structures. Accordingly, the dead weight of buildings and structures were reduced significantly, which ...
Effect of Flexural NSM-FRP Bars on the Shear Strength of Reinforced Concrete Beams
(2019-05)
Strengthening of reinforced concrete (RC) members in flexure and shear, using fiber-reinforced polymer (FRP) laminates and near surface mounted (NSM) bars has been developed over the last few decades. Conventionally, FRP ...
Experimental Study of Punching Shear Resistance of Synthetic Fiber Reinforced Concrete Interior Slabs
(2016-09)
This study experimentally explores the suitability of Synthetic Fiber-Reinforced Concrete (SNFRC) as a feasible method for improving the punching shear strength of two-way slabs. The investigation involved interior flat ...
Numerical Study of Localization Failure in Structural Steel Under Impact Loading
(2011-10)
High quality steels are used as a skeleton supporting many infrastructure constructions like, for example, skyscrapers, arenas, stadiums, bridges and others. The likelihood that these structures could be severely damaged ...
Experimental Investigation of FRP-Reinforced Concrete Columns Under Concentric and Eccentric Loading
(2019-06)
The problem of corrosion of steel in reinforced concrete (RC) structures has urged the need for alternative reinforcement materials. One possible alternative is fiber-reinforced polymer (FRP) bars, which are non-corrosive, ...
Effect of Concrete Type on Flexural Behavior of Concrete Beams Reinforced with HSS Bars
(2016-03)
High-Strength Steel (HSS) bars can be a promising alternative to commonly used mild steel since they have the potential of making more efficient use of highperformance concrete and reducing the required number and size of ...
Novel Near-Field Microwave Testing Method for Outdoor Insulators
(2011-06)
Outdoor insulators are very vital in providing energized overhead lines mechanical support and electrical insulation from grounded structures. Insulators can be divided according to the material they are made of into glass, ...
Flexural Behavior of Reinforced Concrete Beams Strengthened with Externally Bonded Hybrid Systems
(2017-12)
The demand for strengthening of aging reinforced concrete (RC) structures are continuously rising. Carbon fiber reinforced polymers (CFRP) are the most widely used externally bonded-reinforcing (EBR) materials for strengthening ...