Show simple item record

dc.contributor.authorGadalla, Mohamed
dc.contributor.authorTalaat A., Ibrahim
dc.contributor.authorHassan, Mohammed A.M
dc.date.accessioned2016-10-20T06:19:26Z
dc.date.available2016-10-20T06:19:26Z
dc.date.issued2013-11
dc.identifier.citationGadalla, Mohamed, Talaat A. Ibrahim, and Mohamed A.M. Hassan. "Performance characteristics of an ammonia-water absorption heat pump system." International Journal of Energy Research 37, no. 4 (2013): 1917-1927en_US
dc.identifier.issn1099-114X
dc.identifier.urihttp://hdl.handle.net/11073/8560
dc.description.abstractThe influences of the performance parameters and the heat transfer characteristics of the absorption heat pump using ammonia-water mixture are theoretically carried out. There is a pronounced effect of the ammonia concentration ξ after rectifier on the temperature glides that has been investigated. At ξ=0.9000 and saturation pressures of 75 and 0.5bar, the temperature glides are 64.4°C and 81.21°C, respectively, whereas these glides are 0°C and 16.1°C at ξ=0.9999 and at the same pressures. This mixture property considerably affects the absorption system performance and the design of the rectifier as well as other absorption components. A correlation of the Nusselt number, Nu, is developed and compared with some published work in the literature for plate type heat exchanger. The effects of ammonia concentration ξ, mass fraction spread Δξ, specific solution circulation ratio f, and pressure ratio Rp on the refrigerant mass flow rate, the pressure drop, and the heat transfer coefficients during the condensation, the evaporation, and the absorption processes are investigated. It was found that increasing ammonia mass fraction spread Δξ results in both specific circulation ratio f and Rp that have insignificant effects on the refrigerant mass flow rate. Mounting Δξ at constant f reduces the pressure drop gradually and subsequently starts to increase as Δξ escalates. The ammonia concentration ξ has insignificant effect on the evaporation heat transfer coefficient but has a little effect on the condensation and the absorber heat transfer coefficients. The ammonia mass fraction spread Δξ and f have considerable effects on the heat transfer coefficient for different absorption heat pump components. Rp has a pronounced effect on the evaporation heat transfer coefficient, although it has a slight effect on the condensation and the absorber heat transfer coefficients. The effect of Rp on the heat transfer coefficient may be eliminated in the absorber for Δξ>0.18.en_US
dc.language.isoen_USen_US
dc.relation.ispartofseriesInternational Journal of Energy Researchen_US
dc.relation.urihttp://dx.doi.org/10.1002/er.2992en_US
dc.titlePerformance characteristics of an ammonia-water absorption heat pump systemen_US
dc.typeArticleen_US
dc.identifier.doi10.1002/er.2992


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record